Signs of bad pressurestat ??

Need help with equipment usage or want to share your latest discovery?
CSME9
Posts: 503
Joined: 19 years ago

#1: Post by CSME9 »

Isomac TEA with 3 yr old mater P stat
Power light is on.
Boiler heats up, green and red lights cycle on/off ok.
Drain 5-6 ounces of water thru group and both green & red lights turn off, boiler pressure starts dropping from 1.2 to .06 then red light goes back on and cycles again to 1.2.

Problem started 3 days ago after a boiler and HX descale.

Thanks, WS

User avatar
another_jim
Team HB
Posts: 13947
Joined: 19 years ago

#2: Post by another_jim »

The red and green light are connected to the normally closed and open sides of the same switch. If both go off, that switch is jamming, and the pstat needs to be replaced. This is different from the pressure diaphragm freezing into one position, since that can sometimes be "exercised" back to life.
Jim Schulman

User avatar
Randy G.
Posts: 5340
Joined: 17 years ago

#3: Post by Randy G. »

Started after a descale might mean that there is loose scale that worked its way up into the the plumbing of the pressurestat or the diaphragm. mIght try removing it and cleaning it. maybe.