I've been restoring a second Faema Compact. It was working properly until today. I replaced the old Ulka with a newer one. The newer Ulkas only have two connections, so I left the third (ground) unconnected. Everything appeared to work fine until I tested the autofill. It had previously been working fine, but this time it energized the 3-way solenoid, and the pump did not activate. The autofill solenoid did not activate either. I'm pretty sure that the wiring is hooked up correctly because it was previously working. Has anyone ever heard of this? Could this have something to do with the new pump? Thanks in advance.

frankmoss (original poster)
Posts: 125
Joined: 14 years ago

#2: Post by frankmoss (original poster) »

Problem solved. For future reference, I had two wires switched on the main switch on the front of the machine.